600VPR-310/520| Voltage Protection Relay, 3Ø-3W, phase sequence/failure ^over/under voltage, range 154..520VAC, trip delay 0.2..10sec, 1CO (SPDT) 5A 250VAC, TS35
600VPR-310/520| Voltage Protection Relay, 3Ø-3W, phase sequence/failure ^over/under voltage, range 154..520VAC, trip delay 0.2..10sec, 1CO (SPDT) 5A 250VAC, TS35



Surge Arrester V20-4+FS-275, T2, Uc 275VAC, discharge current (8/20μs)| Imax 40kA ^In 20kA, Up ≤1.5kV, tA ≤25ns, FS 0.5A 250VAC/ 3A 30VDC| 1.5mm2, 2.5..25mm², TN-S,  VDE, TÜV, CB, CE, MaxPro
Image is illustrative
Surge Arrester V20-4+FS-275, T2, Uc 275VAC, discharge current (8/20μs)| Imax 40kA ^In 20kA, Up ≤1.5kV, tA ≤25ns, FS 0.5A 250VAC/ 3A 30VDC| 1.5mm2, 2.5..25mm², TN-S, VDE, TÜV, CB, CE, MaxPro
Code: V20-4-FS-275
Price
55,20 €  /pc
Manufacturer :
Availability:
In Stock
Weight:
0.4361 kg/pc
Volume:
0.0007 m3/pc

• Type 2 AC surge protection device
• Nominal/maximum discharge current [In/Imax]:20kA/40kA
• Varistor voltage limiting technology, low residual voltage design
• Pluggable design and internal thermal disconnection devices
• Operating/fault indication, optional remote signal
• Conform to IEC 61643-11,EN 61643-11,GB/T 18802.11

Technology Parameters
AC Working Voltage[ Un ]230VAC
Maximum Continuous Operating Voltage[ Uc ]275VAC
Temporary Overvoltage Test Value TOV-5s [Tolerance][ Ut ]335VAC
Temporary Overvoltage Test Value TOV-120min [Disconnection][ Ut ]440VAC
Nominal Discharge Current [8/20µs][ In ]20kA
Maximum Discharge Current [8/20µs][ Imax ]40kA
Voltage Protection Level[ Up ]≤1.5kV
Short-circuit Current Rating [backup SCB or FUSE][ Isccr ]25kA
Response Time[ tA ]≤25ns
Thermal Disconnection DeviceInsertion
Max. Backup Fuse63A gG fuse
Mechanical Data
Wiring MethodScrew terminal 2.5–25mm² [busbar can be used]
Normal/Fault DisplayGreen/Red
Remote SignalYes
Maximum Remote Signal Load Voltage/current0.5A 250VAC / 3A 30VDC
Maximum Cross-sectional Area Of Remote Signal Connection Line1.5mm²
Installation35mm DIN rail
Operating Temperature Range[ Tu ]-40..85°C
Protection LevelIP20
Enclosure MaterialThermoplastic materials, UL94-V0