Elit logo e-Elit - leading
electronic and automation component
online distributor
Customer service Mo-Fr 9-17
Call: +49 (0) 511-69608385

Elit shopping basket
Items: Total:
0
0,00 €
    search
Log in
Username/Email Address:

Password:
Show all products categ.
Need assistance?
Featured Products!
Analog Output Module Micro850, 4-ch., ±10V/0..20mA, drawn 160mA 5VDC, TS35, panel mount, Allen-Bradley
Analog Output Module Micro850, 4-ch., ±10V/0..20mA, drawn 160mA 5VDC, TS35, panel mount, Allen-Bradley



Communication Processor CP343-1, Simatic S7-300 » ind. Ethernet via ISO, TCP/IP, ProfiNet IO-controller/device, int. 2port switch ERTEC200S7-COMM., fetch/write, send/rcvw., w.o RFC1006, multicast DHCP, NTC-CPU sync, diagnostic, 2xRJ45 w. 10/100Mbit/s
Image is illustrative
Communication Processor CP343-1, Simatic S7-300 » ind. Ethernet via ISO, TCP/IP, ProfiNet IO-controller/device, int. 2port switch ERTEC200S7-COMM., fetch/write, send/rcvw., w.o RFC1006, multicast DHCP, NTC-CPU sync, diagnostic, 2xRJ45 w. 10/100Mbit/s
Code: 6GK7343-1EX30-0XE0
Price (indicative)
1.127,10 €  /pc
Manufacturer :
Availability:
21 days
Weight:
0.297 kg/pc
Volume:
0.001 m3/pc
 

Communication Processor CP343-1, Simatic S7-300 » ind. Ethernet via ISO ?TCP/IP, ProfiNet IO-controller/device, int. 2port switch ERTEC200S7-COMM., fetch/write, send/rcvw. ?w.o RFC1006, multicast DHCP, NTC-CPU sync, diagnostic, 2xRJ45 w. 10/100Mbit/s

COMMUNIKATIONSPROCESSOR CP343-1 FOR CONNECTING SIMATIC S7-300 TO IND. ETHERNET VIA ISO AND TCP/IP, PROFINET IO-CONTROLLER OR PROFINET IO-DEVICE, INTEGR. 2-PORT SWITCH ERTEC200 S7-COMM., FETCH/WRITE, SEND/RCV W. AND W/O RFC1006,MULTICAST DHCP, NTC-CPU SYNC, DIAGNOSTIC, INITIALIZATION VIA LAN, 2 X RJ45 CONNECT. FOR LAN WITH 10/100 MBIT/S
Transmission rate
Transfer rate
● at the 1st interface 10 ... 100 Mbit/s
Interfaces
Number of interfaces / acc. to Industrial Ethernet 2
Number of electrical connections
● at the 1st interface / acc. to Industrial Ethernet 2
● for power supply 1
Type of electrical connection
● at the 1st interface / acc. to Industrial Ethernet RJ45 port
● of Industrial Ethernet interface RJ45 port
● for power supply 2-pole plugable terminal block
Supply voltage, current consumption, power loss
Type of voltage / of the supply voltage DC
Supply voltage / 1 / from backplane bus 5 V
Supply voltage 24 V
Supply voltage / external 24 V
Supply voltage / external / at DC / Rated value 24 V
Relative positive tolerance / at DC / at 24 V 20 %
Relative negative tolerance / at DC / at 24 V 15 %
Consumed current
● from backplane bus / at DC / at 5 V / typical 0.2 A
● from external supply voltage / at DC / at 24 V / typical 0.16 A
● from external supply voltage / at DC / at 24 V / maximum 0.2 A
Power loss [W] 5.8 W
Permitted ambient conditions
Ambient temperature
● for vertical installation / during operation 0 ... 40 °C
● for horizontally arranged busbars / during operation 0 ... 60 °C
● during storage -40 ... +70 °C
● during transport -40 ... +70 °C
Relative humidity / at 25 °C / without condensation / during operation / maximum 95 %
Protection class IP IP20
Design, dimensions and weight
Module format Compact module S7-300 single width
Width 40 mm
Height 125 mm
Depth 120 mm
Net weight 0.22 kg
Mounting type
● S7-300 rail mounting Yes
Performance data / open communication
Number of possible connections / for open communication / by means of SEND/RECEIVE blocks / maximum 16
Amount of data
● as user data per ISO connection / for open communication / by means of SEND/RECEIVE blocks / maximum 8 Kibyte
● as user data per ISO on TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum 8 Kibyte
● as user data per TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum 8 Kibyte
● as user data per UDP connection / for open IE communication / by means of SEND/RECEIVE blocks / maximum 2 Kibyte
Number of Multicast stations 16
Performance data / S7 communication
Number of possible connections / for S7 communication
● maximum 16
Performance data / multi-protocol mode
Number of active connections / with multi-protocol mode 32
Performance data / PROFINET communication / as PN IO-Controller
Number of PN IO devices / on PROFINET IO controller / usable / total 32
Number of external PN IO lines / with PROFINET / per rack 1
Amount of data
● as user data for input variables / as PROFINET IO controller / maximum 1 Kibyte
● as user data for input variables / as PROFINET IO controller / maximum 1 Kibyte
● as user data for input variables per PN IO device / as PROFINET IO controller / maximum 1433 byte
● as user data for output variables per PN IO device / as PROFINET IO controller / maximum 1433 byte
● as user data for input variables per PN IO device / for each sub-module as PROFINET IO controller / maximum 240 byte
● as user data for output variables per PN IO device / for each sub-module as PROFINET IO controller / maximum 240 byte
Performance data / PROFINET communication / as PN IO-Device
Product function / PROFINET IO device Yes
Amount of data
● as user data for input variables / as PROFINET IO device / maximum 512 byte
● as user data for input variables / as PROFINET IO device / maximum 512 byte
● as user data for input variables / for each sub-module as PROFINET IO device 240 byte
● as user data for input variables / for each sub-module as PROFINET IO device 240 byte
● as user data for the consistency area for each sub-module 240 byte
Number of submodules / per PROFINET IO-Device 32
Performance data / telecontrol
Protocol / is supported
● TCP/IP Yes
Product function / MIB support Yes
Protocol / is supported
● SNMP v1 Yes
● DCP Yes
● LLDP Yes
Configuration software
● required STEP 7 V5.4 SP2 or higher / STEP 7 Professional V11 (TIA Portal) or higher
Identification & maintenance function
● I&M0 - device-specific information Yes
● I&M1 – higher-level designation/location designation Yes
Product functions / Diagnosis
Product function / Web-based diagnostics Yes
Product functions / switch
Product feature / Switch Yes
Product function
● switch-managed No
● with IRT / PROFINET IO switch Yes
● Configuration with STEP 7 Yes
Product functions / Redundancy
Product function
● Ring redundancy Yes
● Redundancy manager No
● Parallel Redundancy Protocol (PRP)/operation in the PRP-network Yes
Protocol / is supported / Media Redundancy Protocol (MRP) Yes
Product functions / Security
Product function
● password protection for Web applications No
● ACL - IP-based Yes
● ACL - IP-based for PLC/routing No
● switch-off of non-required services Yes
● Blocking of communication via physical ports Yes
● log file for unauthorized access No
Product functions / Time
Product function / SICLOCK support Yes
Product function / pass on time synchronization Yes
Protocol / is supported
● NTP Yes
Accessories
Further Information / Internet Links
Internet-Link
● to website: Selector SIMATIC NET SELECTION TOOL http://www.siemens.com/snst
● to website: Industrial communication http://www.siemens.com/simatic-net
● to website: Industry Mall https://mall.industry.siemens.com
● to website: Information and Download Center http://www.siemens.com/industry/infocenter
● to website: Image database http://automation.siemens.com/bilddb
● to website: CAx Download Manager http://www.siemens.com/cax
● to website: Industry Online Support https://support.industry.siemens.com
Security information
Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action(e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit http://www.siemens.com/industrialsecurity. To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit http://support.automation.siemens.com. (V3.4)
last modified: 11/13/2017
 
 
AIS.Hensch | e-mail: info@ais-deutschland.de | +49 (0) 511-69608385 | 2021 ©


 
X
 
X