IDC Connector, M12 4pin, shielded, Ethernet, 4A 32V, Allen-Bradley
IDC Connector, M12 4pin, shielded, Ethernet, 4A 32V, Allen-Bradley



Scalance X308-2, Managed Plus IE Switch, 2x 1000 Mbit/s MM SC 1x 10/100/1000 Mbit/s, 7x 10/100 Mbit/s RJ45 ports, LED diagnostics, PROFINET IO device, network management, integrated rotundancy manager, Siemens
Image is illustrative
Scalance X308-2, Managed Plus IE Switch, 2x 1000 Mbit/s MM SC 1x 10/100/1000 Mbit/s, 7x 10/100 Mbit/s RJ45 ports, LED diagnostics, PROFINET IO device, network management, integrated rotundancy manager, Siemens
Code: 6GK5308-2FL10-2AA3
Price (indicative)
2.660,90 €  /pc
Manufacturer :
Availability:
28 days
Weight:
1.5435 kg/pc
Volume:
0.0124 m3/pc
 

Scalance X308-2, Managed Plus IE Switch, 2x 1000 Mbit/s MM SC 1x 10/100/1000 Mbit/s ˄7x 10/100 Mbit/s RJ45 ports, LED diagnostics, PROFINET IO device, network management, integrated redundancy manager, Siemens

SCALANCE X308-2, managed plus IE switch, 2x 1000 Mbit/s MM SC 1x 10/100/1000 Mbit/s and 7x 10/100 Mbit/s RJ45 ports, LED diagnostics, error signaling Contact with select/set button, PROFINET IO device, network management, Integrated redundancy manager, office features (RSTP, VLAN, IGMP,..) C-plug in scope of delivery
Product type designation SCALANCE X308-2
Transmission rate
Transfer rate 10 Mbit/s, 100 Mbit/s, 1000 Mbit/s
Interfaces / for communication / integrated
Number of electrical connections
● for network components or terminal equipment 8
Number of 10/100 Mbit/s RJ45 ports / Integrated
● with securing collar 7
Number of 10/100/1000 Mbit/s RJ45 ports / Integrated
● with securing collar 1
Number of 1000 Mbit/s SC ports
● for multimode 2
Interfaces / others
Number of electrical connections
● for signaling contact 1
● for power supply 1
● for redundant voltage supply 2
Type of electrical connection
● for signaling contact 2-pole terminal block
● for power supply 3-pole terminal block, permanently installed
design of the removable storage
● C-PLUG Yes
Signal-Inputs/outputs
Operating voltage / of the signaling contacts
● at DC / Rated value 24 V
Operating current / of the signaling contacts
● at DC / maximum 0.1 A
Supply voltage, current consumption, power loss
Type of voltage supply / redundant power supply unit No
Type of voltage / of the supply voltage DC
Supply voltage
● external 24 V
● external / minimum 18 V
● external / maximum 32 V
Product component / fusing at power supply input Yes
Fuse protection type / at input for supply voltage F 3 A / 32 V
Consumed current / maximum 0.4 A
Power loss [W]
● at DC / at 24 V 9.6 W
Permitted ambient conditions
Ambient temperature
● during operation -10 ... +60 °C
● during storage -40 ... +70 °C
● during transport -40 ... +70 °C
Relative humidity
● at 25 °C / without condensation / during operation / maximum 95 %
Protection class IP IP30
Design, dimensions and weight
Design compact
Width 120 mm
Height 125 mm
Depth 123 mm
Net weight 1.4 kg
Mounting type When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted.
● 19-inch installation No
● 35 mm DIN rail mounting Yes
● wall mounting Yes
● S7-300 rail mounting Yes
● S7-1500 rail mounting No
Product properties, functions, components / general
Cascading in the case of a redundant ring / at reconfiguration time of <\~0.3\~s 100
Cascading in cases of star topology any (depending only on signal propagation time)
Product functions / management, configuration
Product function
● CLI Yes
● web-based management Yes
● MIB support Yes
● TRAPs via email Yes
● Configuration with STEP 7 Yes
● RMON Yes
● Port mirroring Yes
● multiport mirroring Yes
● CoS Yes
● PROFINET IO diagnosis Yes
PROFINET conformity class B
Product function / switch-managed Yes
Protocol / is supported
● Telnet Yes
● HTTP Yes
● HTTPS Yes
● TFTP Yes
● FTP Yes
● BOOTP Yes
● GMRP Yes
● DCP Yes
● LLDP Yes
● SNMP v1 Yes
● SNMP v2 Yes
● SNMP v3 Yes
● IGMP (snooping/querier) Yes
Identification & maintenance function
● I&M0 - device-specific information Yes
● I&M1 – higher-level designation/location designation Yes
Product functions / Diagnosis
Product function
● Port diagnostics Yes
● Statistics Packet Size Yes
● Statistics packet type Yes
● Error statistics Yes
● SysLog Yes
Product functions / VLAN
Product function
● VLAN - port based Yes
● VLAN - protocol-based No
● VLAN - IP-based No
● VLAN dynamic Yes
Number of VLANs / maximum 255
Number of VLANs - dynamic / maximum 255
Protocol / is supported / GVRP Yes
Product functions / DHCP
Product function
● DHCP client Yes
● DHCP Option 82 Yes
● DHCP Option 66 Yes
● DHCP Option 67 Yes
Product functions / Redundancy
Product function
● Ring redundancy Yes
● High Speed Redundancy Protocol (HRP) Yes
● high speed redundancy protocol (HRP) with redundancy manager Yes
● high speed redundancy protocol (HRP) with standby redundancy Yes
Protocol / is supported / Media Redundancy Protocol (MRP) Yes
Product function
● media redundancy protocol (MRP) with redundancy manager Yes
● redundancy procedure STP Yes
● redundancy procedure RSTP Yes
● redundancy procedure MSTP Yes
● Passive listening Yes
Protocol / is supported
● STP/RSTP Yes
● STP Yes
● RSTP Yes
● MSTP Yes
● RSTP big network support Yes
● LACP Yes
Product functions / Security
Product function
● ACL - MAC-based Yes
● ACL - port/MAC-based Yes
● IEEE 802.1x (radius) Yes
● Broadcast/Multicast/Unicast Limiter Yes
● broadcast blocking Yes
Protocol / is supported
● SSH Yes
Product functions / Time
Product function
● SICLOCK support Yes
Protocol / is supported
● NTP Yes
● SNTP Yes
● IEEE 1588 profile default No
Standards, specifications, approvals
Standard
● for FM FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4
● for hazardous zone EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X
● for safety / from CSA and UL UL 60950-1, CSA C22.2 No. 60950-1
● for hazardous zone / from CSA and UL UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4
● for emitted interference EN 61000-6-4:2007 (Class A)
● for interference immunity EN 61000-6-2:2005
Standards, specifications, approvals / CE
Certificate of suitability / CE marking Yes
Standards, specifications, approvals / miscellaneous
Certificate of suitability EN 61000-6-2:2005, EN 61000-6-4:2007
● C-Tick Yes
● Railway application in accordance with EN 50155 No
● KC approval Yes
Standards, specifications, approvals / ship classification
Marine classification association
● American Bureau of Shipping Europe Ltd. (ABS) Yes
● Bureau Veritas (BV) Yes
● Det Norske Veritas (DNV) No
● Germanische Lloyd (GL) No
● DNV GL Yes
● Polski Rejestr Statkow (PRS) Yes
● Royal Institution of Naval Architects (RINA) No
Standards, specifications, approvals / product conformity
MTBF 25 y
Further Information / Internet Links
Internet-Link
● to website: Selector SIMATIC NET SELECTION TOOL http://www.siemens.com/snst
● to website: Industrial communication http://www.siemens.com/simatic-net
● to website: Industry Mall https://mall.industry.siemens.com
● to website: Information and Download Center http://www.siemens.com/industry/infocenter
● to website: Image database http://automation.siemens.com/bilddb
● to website: CAx Download Manager http://www.siemens.com/cax
● to website: Industry Online Support https://support.industry.siemens.com
Security information
Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action(e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit http://www.siemens.com/industrialsecurity. To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit http://support.automation.siemens.com. (V3.4)
last modified: 10/30/2018
 
 
AIS.Hensch | e-mail: info@ais-deutschland.de | +49 (0) 511-69608385 | 2021 ©


 