Coding element DSTV COST4, Weidmüller
Coding element DSTV COST4, Weidmüller



Simatic ET 200MP, ProfiNet IO-Device Interface Module IM 155-5 PN ST, » 12 IO-modules w.o add. PS, » 30 IO-modules w. add. PS shared device, MRP, IRT ≥0.25ms, isochronicity FW-update, I&M0..3, FSU w. 500ms, Siemens
Image is illustrative
Simatic ET 200MP, ProfiNet IO-Device Interface Module IM 155-5 PN ST, » 12 IO-modules w.o add. PS, » 30 IO-modules w. add. PS shared device, MRP, IRT ≥0.25ms, isochronicity FW-update, I&M0..3, FSU w. 500ms, Siemens
Code: 6ES7155-5AA01-0AB0
Price (indicative)
556,10 €  /pc
Manufacturer :
Availability:
21 days
Weight:
0.377 kg/pc
Volume:
0.001 m3/pc
 

Simatic ET 200MP, ProfiNet IO-Device Interface Module IM 155-5 PN ST, » 12 IO-modules w.o add. PS, » 30 IO-modules w. add. PS shared device, MRP, IRT ≥0.25ms, isochronicity FW-update, I&M0..3, FSU w. 500ms, Siemens

SIMATIC ET 200MP. PROFINET IO-DEVICE INTERFACEMODULE IM 155-5 PN ST FOR ET 200MP ELEKTRONIKMODULES; UP TO 12 IO-MODULES WITHOUT ADDITIONAL PS; UP TO 30 IO- MODULES WITH ADDITIONONAL PS SHARED DEVICE; MRP; IRT >=0.25MS; ISOCHRONICITY FW-UPDATE; I&M0...3; FSU WITH 500MS
General information
Product type designation IM 155-5 PN ST
HW functional status FS01
Firmware version V4.1.0
Vendor identification (VendorID) 0x002A
Device identifier (DeviceID) 0X0312
Product function
● I&M data Yes; I&M0 to I&M3
Engineering with
● STEP 7 TIA Portal configurable/integrated as of version V14 or higher with HSP 0223 / integrated with V15 or higher
● STEP 7 configurable/integrated as of version GSDML V2.32
● PROFINET as of GSD version/GSD revision V2.3 / -
Configuration control
via user data No
via dataset Yes
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Short-circuit protection Yes
Mains buffering
● Mains/voltage failure stored energy time 10 ms
Input current
Current consumption (rated value) 0.2 A
Current consumption, max. 1.2 A
Inrush current, max. 9 A
I²t 0.09 A²·s
Power
Infeed power to the backplane bus 14 W
Power available from the backplane bus 2.3 W
Power loss
Power loss, typ. 4.5 W
Address area
Address space per module
● Address space per module, max. 256 byte; per input / output
Address space per station
● Address space per station, max. 512 byte; per input / output
Hardware configuration
Integrated power supply Yes
System power supply can be plugged in to left of IM Yes
Number of permissible power segments 3
Rack
● Modules per rack, max. 30; I/O modules
Interfaces
Number of PROFINET interfaces 1
1. Interface
Interface types
● Number of ports 2
● integrated switch Yes
● RJ 45 (Ethernet) Yes
Protocols
● PROFINET IO Device Yes
● Media redundancy Yes; PROFINET MRP
Interface types
RJ 45 (Ethernet)
● Transmission procedure PROFINET with 100 Mbit/s full duplex (100BASE-TX)
● 100 Mbps Yes
● Autonegotiation Yes
● Autocrossing Yes
Protocols
PROFINET IO Device
Services
— Isochronous mode Yes
— Open IE communication Yes
— IRT Yes
— PROFIenergy No
— Prioritized startup Yes
— Shared device Yes
— Number of IO Controllers with shared device, max. 2
Redundancy mode
● MRP Yes
● MRPD No
● PROFINET system redundancy (S2) No
● Redundant PROFINET configuration (R1) No
Open IE communication
● TCP/IP Yes
● SNMP Yes
● LLDP Yes
Isochronous mode
Isochronous operation (application synchronized up to terminal) Yes
Equidistance Yes
shortest clock pulse 250 µs
max. cycle 4 ms
Interrupts/diagnostics/status information
Status indicator Yes
Alarms Yes
Diagnostics function Yes
Diagnostics indication LED
● RUN LED Yes; Green LED
● ERROR LED Yes; Red LED
● MAINT LED Yes; Yellow LED
● Connection display LINK TX/RX Yes; 2x green-yellow LEDs
Potential separation
between backplane bus and electronics No
between PROFINET and all other circuits Yes
between supply and all other circuits No
Isolation
Isolation tested with 707 V DC (type test)
Ambient conditions
Ambient temperature during operation
● horizontal installation, min. 0 °C
● horizontal installation, max. 60 °C
● vertical installation, min. 0 °C
● vertical installation, max. 40 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max. 2 000 m
Connection method
ET-Connection
● via BU/BA Send No
Dimensions
Width 35 mm
Height 147 mm
Depth 129 mm
last modified: 05/30/2019
 
 