Contactor CTX³ 225, 132kW 225/275A 3x400VAC, aux. 2NO, 2NC 16A 240VAC, cv 24VAC/DC, panel mount, Legrand
Contactor CTX³ 225, 132kW 225/275A 3x400VAC, aux. 2NO, 2NC 16A 240VAC, cv 24VAC/DC, panel mount, Legrand



Sitop PSU200M, Stabilized Power Supply, input 120/230-500VAC, output 10A 24VDC, Siemens
Image is illustrative
Sitop PSU200M, Stabilized Power Supply, input 120/230-500VAC, output 10A 24VDC, Siemens
Code: 6EP1334-3BA10
Price (indicative)
226,10 €  /pc
Manufacturer :
Availability:
ask for dd
Weight:
0.84 kg/pc
Volume:
0.0027 m3/pc
 

Sitop PSU200M, Stabilized Power Supply, input 120/230-500VAC, output 10A 24VDC, Siemens

SITOP PSU200M 24 V/10 A
SITOP PSU200M 10 A Stabilized power supply input: 120/230-500 V AC output: DC 24 V/10 A
Input
Input 1-phase and 2-phase AC
● Note Set by means of selector switch on the device
Supply voltage
● 1 at AC 120 ... 230 V
● 2 at AC 230 ... 500 V
Input voltage
● 1 at AC 85 ... 264 V
● 2 at AC 176 ... 550 V
Wide-range input Yes
Overvoltage resistance 1300 Vpeak, 1.3 ms
Mains buffering at Iout rated, min. 25 ms; at Vin = 120/230 V, typ. 150 ms at Vin = 400 V
Rated line frequency 1 50 Hz
Rated line frequency 2 60 Hz
Rated line range 47 ... 63 Hz
Input current
● at rated input voltage 120 V 4.4 A
● at rated input voltage 230 V 2.4 A
● at rated input voltage 500 V 1.1 A
Switch-on current limiting (+25 °C), max. 35 A
I²t, max. 4 A²·s
Built-in incoming fuse T 6.3 A (not accessible)
Protection in the mains power input (IEC 898) Recommended miniature circuit breaker at 1-phase operation: from 6 A (10 A) characteristic C (B); required at 2-phase operation: circuit breaker 2-pole connected or circuit breaker 3RV2011-1EA10 (setting 3.8 A) or 3RV2711-1ED10 (UL 489) at 230 V; 3RV2011-1DA10 (setting 3 A) or 3RV2711-1DD10 (UL 489) at 400/500 V
Output
Output Controlled, isolated DC voltage
Rated voltage Vout DC 24 V
Total tolerance, static ± 3 %
Static mains compensation, approx. 0.1 %
Static load balancing, approx. 0.1 %
Residual ripple peak-peak, max. 50 mV
Spikes peak-peak, max. (bandwidth: 20 MHz) 200 mV
Adjustment range 24 ... 28.8 V
Product function Output voltage adjustable Yes
Output voltage setting via potentiometer
Status display Green LED for 24 V OK
Signaling Relay contact (NO contact, rating 60 V DC/ 0.3 A) for "24 V OK"
On/off behavior Overshoot of Vout approx. 3 %
Startup delay, max. 1 s
Voltage rise, typ. 50 ms
Rated current value Iout rated 10 A
Current range 0 ... 10 A
● Note +60 ... +70 °C: Derating 2%/K (at 120 V, 230 V) or 3.5%/K (at 400 V)
Supplied active power typical 240 W
Short-term overload current
● at short-circuit during operation typical 30 A
Duration of overloading capability for excess current
● at short-circuit during operation 25 ms
Constant overload current
● on short-circuiting during the start-up typical 12 A
Parallel switching for enhanced performance Yes; switchable characteristic
Numbers of parallel switchable units for enhanced performance 2
Efficiency
Efficiency at Vout rated, Iout rated, approx. 91 %
Power loss at Vout rated, Iout rated, approx. 24 W
Power loss [W] during no-load operation maximum 6 W
Closed-loop control
Dynamic mains compensation (Vin rated ±15 %), max. 0.1 %
Dynamic load smoothing (Iout: 50/100/50 %), Uout ± typ. 3 %
Load step setting time 50 to 100%, typ. 2 ms
Load step setting time 100 to 50%, typ. 2 ms
Setting time maximum 5 ms
Protection and monitoring
Output overvoltage protection < 35 V
Current limitation, typ. 12 A
Property of the output Short-circuit proof Yes
Short-circuit protection Alternatively, constant current characteristic approx. 12 A or latching shutdown
Enduring short circuit current RMS value
● typical 12 A
Overload/short-circuit indicator LED yellow for "overload", LED red for "latching shutdown"
Safety
Primary/secondary isolation Yes
Galvanic isolation Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178
Protection class Class I
Leakage current
● maximum 3.5 mA
● typical 0.32 mA
CE mark Yes
UL/cUL (CSA) approval cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259, cCSAus (CSA C22.2 No. 60950-1, UL 60950-1)
Explosion protection IECEx Ex nA nC IIC T4 Gc; ATEX (EX) II 3G Ex nA nC IIC T4 Gc; cCSAus (CSA C22.2 No. 213, ANSI/ISA-12.12.01) Class I, Div. 2, Group ABCD, T3
FM approval -
CB approval Yes
Marine approval ABS, DNV GL
Degree of protection (EN 60529) IP20
EMC
Emitted interference EN 55022 Class B
Supply harmonics limitation EN 61000-3-2
Noise immunity EN 61000-6-2
Operating data
Ambient temperature
● during operation -25 ... +70 °C
— Note With natural convection; startup tested starting from -40 °C nominal voltage
● during transport -40 ... +85 °C
● during storage -40 ... +85 °C
Humidity class according to EN 60721 Climate class 3K3, no condensation
Mechanics
Connection technology screw-type terminals
Connections
● Supply input L, N, PE: 1 screw terminal each for 0.2 ... 2.5 mm² single-core/finely stranded
● Output +, -: 2 screw terminals each for 0.2 ... 2.5 mm²
● Auxiliary 13, 14 (alarm signal): 1 screw terminal each for 0.14 ... 1.5 mm²
Width of the enclosure 70 mm
Height of the enclosure 125 mm
Depth of the enclosure 121 mm
Required spacing
● top 50 mm
● bottom 50 mm
● left 0 mm
● right 0 mm
Weight, approx. 0.8 kg
Product feature of the enclosure housing for side-by-side mounting Yes
Installation Snaps onto DIN rail EN 60715 35x7.5/15
Electrical accessories Buffer module
MTBF at 40 °C 1 055 408 h
Other information Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)
 
 