Input current |
from backplane bus 5 V DC, max. |
90 mA |
Power loss |
Power loss, typ. |
0.4 W |
Analog inputs |
Number of analog inputs |
8 |
● For resistance measurement |
8 |
permissible input voltage for voltage input (destruction limit), max. |
30 V; 12 V continuous, 30 V for max. 1 s |
permissible input current for current input (destruction limit), max. |
40 mA |
Input ranges |
● Voltage |
Yes |
● Current |
Yes |
● Thermocouple |
No |
● Resistance thermometer |
Yes |
● Resistance |
Yes |
Input ranges (rated values), voltages |
● 0 to +10 V |
Yes |
● Input resistance (0 to 10 V) |
100 kΩ |
● 1 V to 5 V |
Yes |
● Input resistance (1 V to 5 V) |
100 kΩ |
● 1 V to 10 V |
No |
● -1 V to +1 V |
Yes |
● Input resistance (-1 V to +1 V) |
100 kΩ |
● -10 V to +10 V |
Yes |
● Input resistance (-10 V to +10 V) |
100 kΩ |
● -2.5 V to +2.5 V |
No |
● -250 mV to +250 mV |
No |
● -5 V to +5 V |
Yes |
● Input resistance (-5 V to +5 V) |
100 kΩ |
● -50 mV to +50 mV |
Yes |
● Input resistance (-50 mV to +50 mV) |
100 kΩ |
● -500 mV to +500 mV |
Yes |
● Input resistance (-500 mV to +500 mV) |
100 kΩ |
● -80 mV to +80 mV |
No |
Input ranges (rated values), currents |
● 0 to 20 mA |
Yes |
● Input resistance (0 to 20 mA) |
100 Ω |
● -10 mA to +10 mA |
No |
● -20 mA to +20 mA |
Yes |
● Input resistance (-20 mA to +20 mA) |
100 Ω |
● -3.2 mA to +3.2 mA |
No |
● 4 mA to 20 mA |
Yes |
● Input resistance (4 mA to 20 mA) |
100 Ω |
Input ranges (rated values), thermocouples |
● Type B |
No |
● Type C |
No |
● Type E |
No |
● Type J |
No |
● Type K |
No |
● Type L |
No |
● Type N |
No |
● Type R |
No |
● Type S |
No |
● Type T |
No |
● Type U |
No |
● Type TXK/TXK(L) to GOST |
No |
Input ranges (rated values), resistance thermometer |
● Cu 10 |
No |
● Ni 100 |
Yes; Standard/climate |
● Input resistance (Ni 100) |
100 MΩ |
● Ni 1000 |
Yes |
● Input resistance (Ni 1000) |
100 MΩ |
● LG-Ni 1000 |
Yes; Standard/climate |
● Input resistance (LG-Ni 1000) |
100 MΩ |
● Ni 120 |
No |
● Ni 200 |
No |
● Ni 500 |
No |
● Pt 100 |
Yes; Standard/climate |
● Input resistance (Pt 100) |
100 MΩ |
● Pt 1000 |
No |
● Pt 200 |
No |
● Pt 500 |
No |
Input ranges (rated values), resistors |
● 0 to 150 ohms |
No |
● 0 to 300 ohms |
No |
● 0 to 600 ohms |
Yes |
● Input resistance (0 to 600 ohms) |
100 MΩ |
● 0 to 6000 ohms |
Yes |
● Input resistance (0 to 6000 ohms) |
100 MΩ |
Characteristic linearization |
● parameterizable |
Yes |
— for resistance thermometer |
yes; Pt100 standard/air con.; Ni100 standard/air con.; Ni1000 standard/air con.; LG-Ni1000 standard/air con. |
Cable length |
● shielded, max. |
200 m; max. 50 m at 50 mV |
Analog value generation for the inputs |
Measurement principle |
integrating |
Integration and conversion time/resolution per channel |
● Resolution with overrange (bit including sign), max. |
13 bit |
● Integration time, parameterizable |
Yes; 60 / 50 ms |
● Basic conversion time (ms) |
66 / 55 ms |
● Interference voltage suppression for interference frequency f1 in Hz |
50 / 60 Hz |
Encoder |
Connection of signal encoders |
● for current measurement as 2-wire transducer |
Yes; with external supply |
● for current measurement as 4-wire transducer |
Yes |
● for resistance measurement with two-wire connection |
Yes |
● for resistance measurement with three-wire connection |
Yes |
● for resistance measurement with four-wire connection |
Yes |
Errors/accuracies |
Operational error limit in overall temperature range |
● Voltage, relative to input range, (+/-) |
0.6 %; ±0.6 % (±5 V, 10 V, 1 to 5 V, 0 to 10 V); ±0.5 % (±50 mV, 500 mV, 1 V) @ 0 ... +60 °C; ±0.7 % (±5 V, 10 V, 1 to 5 V, 0 to 10 V); ±0.6 % (±50 mV, 500 mV, 1 V) @ -25 ... +70 °C |
● Current, relative to input range, (+/-) |
0.5 %; @ 0 ... +60 °C; ±0.6% @ -25 ... +70 °C; ±20 mA, 0 to 20 mA, 4 to 20 mA |
● Resistance, relative to input range, (+/-) |
0.5 %; @ 0 ... +60 °C; 0.6% @ -25 ... +70 °C; 0 to 6 kohm, 0 to 600 kohm |
● Resistance thermometer, relative to input range, (+/-) |
1 Kelvin (Pt100, Ni100, climate; Ni1000, LG-Ni1000, standard; Ni1000, LG-Ni1000, climate); 1.2 Kelvin (Pt100, Ni100, standard) @ 0 ... +60 °C; 1.2 Kelvin (Pt100, Ni100, climate; Ni1000, LG-Ni1000, standard; Ni1000, LG-Ni1000, climate); 1.4 Kelvin (Pt100, Ni100, standard) @ -25 ... +70 °C |
Basic error limit (operational limit at 25 °C) |
● Voltage, relative to input range, (+/-) |
0.4 %; 0.4% (±5 V, 10 V, 1 to 5 V, 0 to 10 V); 0.3% (±50 mV, 500 mV, 1 V) |
● Current, relative to input range, (+/-) |
0.3 %; ±20 mA, 0 to 20 mA, 4 to 20 mA |
● Resistance, relative to input range, (+/-) |
0.3 %; 0 to 6 kohms, 0 to 600 kohms |
● Resistance thermometer, relative to input range, (+/-) |
1 Kelvin (Pt100, Ni100, standard); 0.8 Kelvin (Pt100, Ni100, climatic; Ni1000, LG-Ni1000, standard; Ni1000, LG-Ni1000, climatic) |
Interrupts/diagnostics/status information |
Diagnostic functions |
No |
Alarms |
● Diagnostic alarm |
No |
● Limit value alarm |
No |
Diagnostic messages |
● Diagnostic information readable |
No |
Diagnostics indication LED |
● Group error SF (red) |
No |
Potential separation |
Potential separation analog inputs |
● between the channels and backplane bus |
Yes |
Isolation |
Isolation tested with |
500 V DC |
Standards, approvals, certificates |
CE mark |
Yes |
UL approval |
Yes; File E239877 |
FM approval |
Yes; CofC 3028431 |
RCM (formerly C-TICK) |
Yes |
KC approval |
Yes |
EAC (formerly Gost-R) |
Yes |
Railway application |
● EN 50121-4 |
No |
● EN 50155 |
No |
Ambient conditions |
Ambient temperature during operation |
● min. |
-25 °C |
● max. |
70 °C; = Tmax; 60 °C @ UL/cUL, ATEX and FM use |
Altitude during operation relating to sea level |
● Ambient air temperature-barometric pressure-altitude |
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) |
Relative humidity |
● With condensation, tested in accordance with IEC 60068-2-38, max. |
100 %; RH incl. condensation/frost (no commissioning under condensation conditions) |
Resistance |
Use in stationary industrial systems |
— to biologically active substances according to EN 60721-3-3 |
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
— to chemically active substances according to EN 60721-3-3 |
Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
— to mechanically active substances according to EN 60721-3-3 |
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
Connection method |
required front connector |
40-pin |
Dimensions |
Width |
40 mm |
Height |
125 mm |
Depth |
117 mm |
Weights |
Weight, approx. |
250 g |