Elit logo e-Elit - leading
electronic and automation component
online distributor
Customer service Mo-Fr 9-17
Call: +49 (0) 511-69608385

Elit shopping basket
Items: Total:
0
0,00 €
    search
Log in
Username/Email Address:

Password:
Show all products categ.
Need assistance?
Featured Products!
Marker CAB3, 1.5..2.5mm², A, Streifen 30stk, Legrand, gelb
Marker CAB3, 1.5..2.5mm², A, Streifen 30stk, Legrand, gelb



Feed-through Terminal Block UT 6 GN, 50stk/pck, Phoenix
Image is illustrative
Feed-through Terminal Block UT 6 GN, 50stk/pck, Phoenix
Code: 3045211
Price
40,00 €  /pk
Package 50pc, unit price 0.8EUR/pc
Manufacturer :
Availability:
28 days
Weight:
0.0149 kg/pc
Volume:
0 m3/pc
 

Feed-through Terminal Block UT 6 GN, 50pcs/pck, Phoenix

General

Number of rows 1
Number of connections 2
Potentials 1
Nominal cross section 6 mm²
Color green
Insulating material PA
Flammability rating according to UL 94 V0
Area of application Railway industry
Machine building
Plant engineering
Process industry
Mounting type NS 35/7,5
Rated surge voltage 8 kV
Degree of pollution 3
Overvoltage category III
Insulating material group I
Maximum load current 57 A (with 10 mm² conductor cross section)
Nominal current IN 41 A
Nominal voltage UN 1000 V
Open side panel Yes
Relative insulation material temperature index (Elec., UL 746 B) 130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
Static insulating material application in cold -60 °C
Surface flammability NFPA 130 (ASTM E 162) passed
Specific optical density of smoke NFPA 130 (ASTM E 662) passed
Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
Smoke gas toxicity NFPA 130 (SMP 800C) passed
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3

Dimensions

Width 8.2 mm
End cover width 2.2 mm
Length 47.7 mm
Height NS 35/7,5 47.5 mm
Height NS 35/15 55 mm

Connection data

Connection method Screw connection
Screw thread M4
Stripping length 10 mm
Tightening torque, min 1.5 Nm
Tightening torque max 1.8 Nm
Connection in acc. with standard IEC 60947-7-1
Note Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area.
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 10 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 8
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 10 mm²
Min. AWG conductor cross section, flexible 24
Max. AWG conductor cross section, flexible 8
Conductor cross section flexible, with ferrule without plastic sleeve min. 0.25 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max. 6 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min. 0.25 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max. 6 mm²
2 conductors with same cross section, solid min. 0.2 mm²
2 conductors with same cross section, solid max. 2.5 mm²
2 conductors with same cross section, stranded min. 0.2 mm²
2 conductors with same cross section, stranded max. 2.5 mm²
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.5 mm²
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 4 mm²
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 0.25 mm²
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 1.5 mm²
Internal cylindrical gage A5

Ambient conditions

Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Permissible humidity (storage/transport) 30 % ... 70 %
Ambient temperature (assembly) -5 °C ... 70 °C
Ambient temperature (actuation) -5 °C ... 70 °C

Standards and Regulations

Connection in acc. with standard CSA
IEC 60947-7-1
Flammability rating according to UL 94 V0

Environmental Product Compliance

China RoHS Environmentally Friendly Use Period = 50 years
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

ECLASS

ECLASS 10.0.1 27141120
ECLASS 11.0 27141120
ECLASS 4.0 27141100
ECLASS 4.1 27141100
ECLASS 5.0 27141100
ECLASS 5.1 27141100
ECLASS 6.0 27141100
ECLASS 7.0 27141120
ECLASS 9.0 27141120

ETIM

ETIM 2.0 EC000897
ETIM 3.0 EC000897
ETIM 4.0 EC000897
ETIM 6.0 EC000897
ETIM 7.0 EC000897

UNSPSC

UNSPSC 6.01 30211811
UNSPSC 7.0901 39121410
UNSPSC 11 39121410
UNSPSC 12.01 39121410
UNSPSC 13.2 39121410
UNSPSC 18.0 39121410
UNSPSC 19.0 39121410
UNSPSC 20.0 39121410
UNSPSC 21.0 39121410
 
 
AIS.Hensch | e-mail: info@ais-deutschland.de | +49 (0) 511-69608385 | 2021 ©


 
X
 
X