Dimmer Valena In´Matic, mech.| Drehdimmer, LEDs 5..75W (10 Lampen), Halogen-/ Leuchtstoffröhren 5..300VA, Glühlampen 5..300W 240VAC, Legrand
Dimmer Valena In´Matic, mech.| Drehdimmer, LEDs 5..75W (10 Lampen), Halogen-/ Leuchtstoffröhren 5..300VA, Glühlampen 5..300W 240VAC, Legrand



DC/DC Converter MINI-PS-48-60DC/24DC/1, 1stk/pck, Phoenix
Image is illustrative
DC/DC Converter MINI-PS-48-60DC/24DC/1, 1stk/pck, Phoenix
Code: 2866271
Price
192,70 €  /pc
Manufacturer :
Availability:
21 days
Weight:
0.2412 kg/pc
Volume:
0.0008 m3/pc
 

DC/DC Converter MINI-PS-48-60DC/24DC/1, 1pcs/pck, Phoenix

Dimensions

Width 22.5 mm
Height 99 mm
Depth 107 mm
Installation distance right/left 0 mm / 0 mm (≤ 70 °C)
Installation distance top/bottom 50 mm / 50 mm (≤ 70 °C)

Ambient conditions

Degree of protection IP20
Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)

Input data

Nominal input voltage range 48 V DC ... 60 V DC
Input voltage range 36 V DC ... 75 V DC
Frequency range DC 0 Hz
Current consumption 0.6 A (48 V DC)
0.5 A (60 V DC)
Inrush current < 15 A (typical)
Mains buffering time typ. 15 ms (48 V DC)
typ. 20 ms (60 V DC)
Input fuse 3.15 A (slow-blow, internal)

Output data

Nominal output voltage 24 V DC ±1 %
Setting range of the output voltage (USet) 22.5 V DC ... 28.5 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IN) 1 A (-25 °C ... 60 °C)
Derating 60 °C ... 70 °C (2.5%/K)
Connection in parallel yes, for assembling redundant systems and increasing efficiency
Connection in series yes
Residual ripple < 40 mVPP
Output power 24 W
Typical response time < 0.5 s
Peak switching voltages nominal load < 50 mVPP (20 MHz)
Maximum power dissipation in no-load condition < 1.2 W
Power loss nominal load max. < 5 W

General

Net weight 0.2 kg
Operating voltage display Green LED
Efficiency > 85 % (at 60 V DC and nominal values)
MTBF (IEC 61709, SN 29500)
> 1147000 h (40 °C)
Insulation voltage input/output 1.5 kV (type test)
1 kV (routine test)
Degree of protection IP20
Protection class II
Housing material Polyamide (PA)
Mounting position horizontal DIN rail NS 35, EN 60715
Assembly instructions alignable: horizontally 0 mm, vertically 50 mm

Connection data, input

Connection method Pluggable screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 14
Stripping length 7 mm
Screw thread M3

Connection data, output

Connection method Pluggable screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 14
Stripping length 7 mm
Screw thread M3

Signaling

Output name DC OK active
Output description UOUT > 21.5 V: High signal
Maximum switching voltage ≤ 24 V DC
Output voltage + 24 V (Signal)
Continuous load current ≤ 20 mA
Status display "DC OK" LED green
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 14
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm
Screw thread M3

Standards

EMC requirements for noise immunity EN 61000-6-1
EN 61000-6-2
EMC requirements for noise emission EN 61000-6-3
EN 61000-6-4
Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
Standard - Safe isolation DIN VDE 0100-410
Rail applications EN 50121-4

Conformance/approvals

UL approvals UL/C-UL listed UL 508
UL/C-UL Recognized UL 60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)

EMC data

Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
Electrostatic discharge EN 61000-4-2
Electromagnetic HF field EN 61000-4-3
Fast transients (burst) EN 61000-4-4
Surge voltage load (surge) EN 61000-4-5
Conducted interference EN 61000-4-6
Voltage dips EN 61000-4-11

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 25;
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

ECLASS

ECLASS 10.0.1 27210901
ECLASS 11.0 27210901
ECLASS 4.0 27210900
ECLASS 4.1 27210900
ECLASS 5.0 27210900
ECLASS 5.1 27210900
ECLASS 6.0 27210900
ECLASS 7.0 27210901
ECLASS 9.0 27210901

ETIM

ETIM 2.0 EC001039
ETIM 3.0 EC001039
ETIM 4.0 EC000599
ETIM 6.0 EC002046
ETIM 7.0 EC002046

UNSPSC

UNSPSC 6.01 30211502
UNSPSC 7.0901 39121004
UNSPSC 11 39121004
UNSPSC 12.01 39121004
UNSPSC 13.2 39121041
UNSPSC 18.0 39121041
UNSPSC 19.0 39121041
UNSPSC 20.0 39121041
UNSPSC 21.0 39121041
 
 