|
|
|
Image is illustrative
|
Inline Terminal IB IL 24/230 DOR4/W-PC-PAC, Phoenix Code:
2862181
Price
Manufacturer
:
Availability:
21 days
|
Weight:
0.1449 kg/pc
|
Volume:
0.0004 m3/pc
|
|
|
|
|
Inline Terminal IB IL 24/230 DOR4/W-PC-PAC, PhoenixNote
Utilization restriction
|
EMC: class A product, see manufacturer's declaration in the download area
|
Dimensions
Dimensional drawing
|
|
Width
|
48.8 mm
|
Height
|
119.8 mm
|
Depth
|
71.5 mm
|
Note on dimensions
|
Housing dimensions
|
Ambient conditions
Ambient temperature (operation)
|
-25 °C ... 55 °C
|
Ambient temperature (storage/transport)
|
-25 °C ... 85 °C
|
Permissible humidity (operation)
|
75 % ... 85 % (in the range of -25°C ... +55°C, appropriate measures against increased humidity (> 85%) must be taken.)
|
Permissible humidity (storage/transport)
|
75 % ... 85 % (slight temporary condensation may sometimes appear on the housing)
|
Air pressure (operation)
|
70 kPa ... 106 kPa (up to 3000 m above sea level)
|
Air pressure (storage/transport)
|
70 kPa ... 106 kPa (up to 3000 m above sea level)
|
Degree of protection
|
IP20
|
General
Mounting type
|
DIN rail
|
Color
|
gray
|
Net weight
|
138 g
|
Note on weight specifications
|
without plug
|
Interfaces
Designation
|
Inline local bus
|
Number
|
2
|
Connection method
|
Via data marshalling
|
Transmission speed
|
500 kbps
|
Inline potentials
Designation
|
Communications power (UL)
|
Supply voltage
|
7.5 V DC (via voltage jumper)
|
Current consumption
|
max. 187 mA
|
Relay outputs
Output name
|
Relay outputs
|
Output description
|
Relay changeover contact
|
Design of digital output
|
Relay
|
Number of outputs
|
4 (floating contacts)
|
Connection method
|
Spring-cage connection
|
Output current
|
max. 3 A (per channel)
|
|
max. 12 A (per module)
|
Nominal output voltage
|
24 V DC
|
|
230 V AC
|
Output voltage range
|
5 V AC ... 253 V AC
|
Switching voltage
|
min. 5 V DC
|
|
max. 250 V DC
|
Electrical isolation
Test section
|
Relay contact / Bus logics 4 kV 50 Hz 1 min.
|
|
Contact/contact 1 kV 50 Hz 1 min.
|
|
Contact / PE 1 kV 50 Hz 1 min.
|
Standards and Regulations
Connection in acc. with standard
|
CUL
|
Protection class
|
I (МЭК 61140, EN 61140, VDE 0140-1)
|
Environmental Product Compliance
China RoHS
|
Environmentally Friendly Use Period = 50 years
|
|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
|
ECLASS
ECLASS 10.0.1 |
27242604
|
ECLASS 11.0 |
27242604
|
ECLASS 4.0 |
27250300
|
ECLASS 4.1 |
27250300
|
ECLASS 5.0 |
27250300
|
ECLASS 5.1 |
27242600
|
ECLASS 6.0 |
27242600
|
ECLASS 7.0 |
27242604
|
ECLASS 9.0 |
27242604
|
ETIM
ETIM 2.0 |
EC001430
|
ETIM 3.0 |
EC001599
|
ETIM 4.0 |
EC001599
|
ETIM 6.0 |
EC001599
|
ETIM 7.0 |
EC001599
|
UNSPSC
UNSPSC 6.01 |
43172015
|
UNSPSC 7.0901 |
43201404
|
UNSPSC 11 |
43172015
|
UNSPSC 12.01 |
43201404
|
UNSPSC 13.2 |
32151602
|
UNSPSC 18.0 |
32151602
|
UNSPSC 19.0 |
32151602
|
UNSPSC 20.0 |
32151602
|
UNSPSC 21.0 |
32151602
|
|
File description
|
File type
|
Download link
|
|
|
|
|
|
|
|
|