Leitungsschutzschalter EPB-63M, 3C 40A 6kA, 25/35mm²| 2..3.5Nm
Leitungsschutzschalter EPB-63M, 3C 40A 6kA, 25/35mm²| 2..3.5Nm



Surge Protection Plug PT 3-HF-12DC-ST, Phoenix
Image is illustrative
Surge Protection Plug PT 3-HF-12DC-ST, Phoenix
Code: 2858043
Price (indicative)
1.273,00 €  /pk
Package 10pc, unit price 127.3EUR/pc
Manufacturer :
Availability:
28 days
Weight:
0.0215 kg/pc
Volume:
0 m3/pc
 

Surge Protection Plug PT 3-HF-12DC-ST, Phoenix

Dimensions

Height 45 mm
Width 17.7 mm
Depth 52 mm
Horizontal pitch 1 Div.
Complete module height 90 mm
Complete module width 17.7 mm
Complete module depth 65.5 mm

Ambient conditions

Ambient temperature (operation) -40 °C ... 85 °C
Altitude max. 2000 m
Degree of protection IP20

General

Housing material PA
Flammability rating according to UL 94 V-0
Color black
Standards for cearances and creepage distances DIN EN 61664-1
IEC 60664-1
Mounting type on base element
Type Male
Number of positions 3
Direction of action Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Arrester can be tested with CHECKMASTER from software version: From SW rev. 1.10

Protective circuit

IEC test classification C1
C2
C3
D1
VDE requirement class C1
C2
C3
D1
Nominal voltage UN 12 V DC
Maximum continuous voltage UC 14 V DC
9.8 V AC
Rated current 450 mA (45 °C)
Operating effective current IC at UC ≤ 5 µA
Residual current IPE < 5 µA (with PT 1X2-BE)
< 1 µA (with PT 1X2+F-BE)
Nominal discharge current In (8/20) µs (line-line) 10 kA
Nominal discharge current In (8/20) µs (line-earth) 10 kA
Nominal discharge current In (8/20) µs (line-signal ground) 10 kA
Pulse discharge current Iimp (10/350) µs 2.5 kA
Total discharge current Itotal (8/20) µs 20 kA
Max. discharge current Imax (8/20) µs maximum (line-line) 10 kA
Max. discharge current Imax (8/20) µs maximum (line-earth) 10 kA
Nominal pulse current Ian (10/1000) µs (line-line) 67 A
Output voltage limitation at 1 kV/µs (line-line) spike ≤ 55 V
Output voltage limitation at 1 kV/µs (line-earth) spike ≤ 55 V (with PT 1X2-BE)
≤ 700 V (with PT 1X2+F-BE)
Output voltage limitation at 1 kV/µs (line-line) static ≤ 25 V
Output voltage limitation at 1 kV/µs (line-earth) static ≤ 25 V
≤ 40 V (with PT 1X2+F-BE)
Residual voltage at In (line-line) ≤ 25 V
Residual voltage at In (line-earth) ≤ 40 V (with PT 1X2-BE)
Residual voltage at In (line-signalground) ≤ 25 V (with PT 1X2-BE)
Residual voltage with Ian (10/1000) µs (line-line) ≤ 25 V
Residual voltage with Ian (10/1000) µs (line-signalground) ≤ 25 V
Voltage protection level Up (line-line) ≤ 50 V (C3 - 25 A)
≤ 80 V (C1 - 1 kV/500 A)
≤ 110 V (C2 - 10 kV / 5 kA)
≤ 80 V (6 kV / 3 kA)
Voltage protection level Up (line-earth) ≤ 50 V (C3 - 25 A)
≤ 85 V (C1 - 1 kV/500 A)
≤ 140 V (C2 - 10 kV / 5 kA)
≤ 100 V (6 kV / 3 kA)
Voltage protection level Up (line-signalground) ≤ 50 V (C3 - 25 A)
Response time tA (line-line) ≤ 500 ns
Response time tA (line-earth) ≤ 500 ns
Input attenuation aE, sym. typ. 0.3 dB (≤ 5 MHz / 100 Ω)
Cut-off frequency fg (3 dB), sym. in 100 Ω system typ. 60 MHz
Capacity (line-line) typ. 30 pF
Resistance per path 2.2 Ω ±10 % (7-8/11-12)
Max. required back-up fuse 500 mA (T)
Impulse durability (line-line) C2 - 10 kV / 5 kA
C3 - 67 A
Impulse durability (line-earth) C2 - 10 kV / 5 kA
C3 - 67 A
D1 - 2.5 kA

Connection data

Connection method Screw connection (in connection with the base element)
Screw thread M3
Tightening torque 0.8 Nm
Stripping length 8 mm
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section solid 0.2 mm² ... 4 mm²
Conductor cross section AWG 24 ... 12

Connection, equipotential bonding

Stripping length 8 mm
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 4 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12

Standards and Regulations

Standards/specifications EN 61643-21/A1 2009
IEC 61643-21/A1 2008

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

ECLASS

ECLASS 10.0.1 27130807
ECLASS 11.0 27130807
ECLASS 4.0 27130800
ECLASS 4.1 27130800
ECLASS 5.0 27130800
ECLASS 5.1 27130800
ECLASS 6.0 27130800
ECLASS 7.0 27130807
ECLASS 9.0 27130807

ETIM

ETIM 2.0 EC000943
ETIM 3.0 EC000943
ETIM 4.0 EC000943
ETIM 6.0 EC000943
ETIM 7.0 EC000943

UNSPSC

UNSPSC 6.01 30212010
UNSPSC 7.0901 39121610
UNSPSC 11 39121610
UNSPSC 12.01 39121610
UNSPSC 13.2 39121620
UNSPSC 18.0 39121620
UNSPSC 19.0 39121620
UNSPSC 20.0 39121620
UNSPSC 21.0 39121620
 
 