Elit logo e-Elit - leading
electronic and automation component
online distributor
Customer service Mo-Fr 9-17
Call: +49 (0) 511-69608385

Elit shopping basket
Items: Total:
0
0,00 €
    search
Log in
Username/Email Address:

Password:
Show all products categ.
Need assistance?
Featured Products!
Connecting Cable NEBU-M12G5-K-5-LE5, 541331
Connecting Cable NEBU-M12G5-K-5-LE5, 541331



Surge Protection Plug PT 2XEX(I)-24DC-ST, 10pcs/pck, Phoenix
Image is illustrative
Surge Protection Plug PT 2XEX(I)-24DC-ST, 10pcs/pck, Phoenix
Code: 2838225
Price (indicative)
2.486,00 €  /pk
Package 10pc, unit price 248.6EUR/pc
Manufacturer :
Availability:
28 days
Weight:
0.0221 kg/pc
Volume:
0 m3/pc
 

Surge Protection Plug PT 2XEX(I)-24DC-ST, 10pcs/pck, Phoenix

Dimensions

Height 44.8 mm
Width 17.5 mm
Depth 51.7 mm
Horizontal pitch 1 Div.
Complete module height 90 mm
Complete module width 17.7 mm
Complete module depth 65.5 mm

Ambient conditions

Ambient temperature (operation) -40 °C ... 85 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Altitude ≤ 2000 m (amsl (above mean sea level))
Degree of protection IP20

General

Housing material PA 6.6
Flammability rating according to UL 94 V-0
Color sky blue RAL 5015
Mounting type on base element
Type Male
Number of positions 4
Direction of action Line-Line & Line-Signal Ground/Shield & Signal Ground/Shield-Earth Ground
Arrester can be tested with CHECKMASTER from software version: From SW rev. 1.00

Protective circuit

IEC test classification C1
C2
C3
D1
Nominal voltage UN 24 V DC
Maximum continuous voltage UC 30 V DC
21 V AC
Rated current 325 mA (40 °C)
Operating effective current IC at UC ≤ 5 µA
Residual current IPE ≤ 4 µA
Nominal discharge current In (8/20) µs (line-line) 10 kA
Nominal discharge current In (8/20) µs (line-earth) 10 kA
Pulse discharge current Iimp (10/350) µs (line-line) 1 kA
Pulse discharge current Iimp (10/350) µs (line-earth) 2 kA (in total)
Total discharge current Itotal (8/20) µs 20 kA
Total discharge current Itotal (10/350) µs 2 kA
Max. discharge current Imax (8/20) µs maximum (line-line) 10 kA
Max. discharge current Imax (8/20) µs maximum (line-earth) 20 kA (in total)
Nominal pulse current Ian (10/1000) µs (line-line) 30 A
Output voltage limitation at 1 kV/µs (line-line) spike ≤ 45 V
Output voltage limitation at 1 kV/µs (line-earth) spike ≤ 1 kV
Output voltage limitation at 1 kV/µs (line-line) static ≤ 45 V
Output voltage limitation at 1 kV/µs (line-earth) static ≤ 1 kV
Residual voltage at In (line-line) ≤ 45 V
Residual voltage with Ian (10/1000) µs (line-line) ≤ 50 V
Voltage protection level Up (line-line) ≤ 45 V (C1 - 0.5 kV / 250 A)
≤ 50 V (C1 - 1 kV/500 A)
≤ 60 V (C2 - 2 kV/1 kA)
≤ 100 V (C2 - 10 kV / 5 kA)
≤ 50 V (C3 - 10 A)
≤ 50 V (C3 - 25 A)
≤ 150 V (D1 - 1 kA)
Voltage protection level Up (line-earth) ≤ 1 kV (C1 - 1 kV/500 A)
≤ 1 kV (C2 - 2 kV/1 kA)
≤ 1 kV (C2 - 10 kV / 5 kA)
≤ 1 kV (D1 - 1 kA)
Response time tA (line-line) ≤ 1 ns
Response time tA (line-earth) ≤ 100 ns
Input attenuation aE, sym. typ. 0.5 dB (≤ 900 kHz / 50 Ω)
typ. 0.2 dB (≤ 300 kHz / 150 Ω)
typ. 0.1 dB (≤ 60 kHz / 600 Ω)
Cut-off frequency fg (3 dB), sym. in 50 Ω system typ. 4.5 MHz
Cut-off frequency fg (3 dB), sym. in 150 Ω system typ. 1.6 MHz
Cut-off frequency fg (3 dB), sym. in 600 Ω system typ. 400 kHz
Resistance per path 2.2 Ω ±10 %
Surge protection fault message none
Max. required back-up fuse 315 mA (T)
Impulse durability (line-line) C1 - 0.5 kV / 250 A
C1 - 1 kV / 500 A
C2 - 2 kV / 1 kA
C2 - 10 kV / 5 kA
C3 - 10 A
C3 - 25 A
D1 - 1 kA
Impulse durability (line-earth) C1 - 1 kV / 500 A
C2 - 2 kV / 1 kA
C2 - 10 kV / 5 kA
D1 - 1 kA
Alternating current carrying capacity (line-earth) 10 A - 1 s

Connection data

Connection method Screw connection (in connection with the base element)
Screw thread M3
Tightening torque 0.5 Nm
Stripping length 8 mm
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section solid 0.2 mm² ... 4 mm²
Conductor cross section AWG 24 ... 12

Standards and Regulations

Standards/specifications EN 61643-21 A2:2013
EN 60079-0 2012
EN 60079-11 2012
EN 60079-26 2007
IEC 61643-21 A2:2012
IEC 60079-0 2011
IEC 60079-11 2011
IEC 60079-26 2006

General

Maximum inner capacitance Ci 1.3 nF
Max. internal inductance Li 1 µH
Maximum inner time factor (Ri/Li) ≤ 0.2 µs
Max. input current Ii 325 mA (T4 / ≤ 80°C)
325 mA (T5 / ≤ 55 °C)
325 mA (T6 / ≤ 40 °C)
Max. input voltage Ui 30 V DC
max. input power Pi 3 W
Ambient temperature (operation) -40 °C ... 80 °C (T4)
-40 °C ... 55 °C (T5)
-40 °C ... 40 °C (T6)

Conformity / approvals

ATEX  II 1G Ex ia IIC T4...T6 Ga
 II 1D Ex ia IIIC T135°C...T85°C Da
IECEx Ex ia IIC T4...T6 Ga
Ex ia IIIC T135 °C...T85 °C Da

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

ECLASS

ECLASS 10.0.1 27130807
ECLASS 11.0 27130807
ECLASS 4.0 27130800
ECLASS 4.1 27130800
ECLASS 5.0 27130800
ECLASS 5.1 27130800
ECLASS 6.0 27130800
ECLASS 7.0 27130807
ECLASS 9.0 27130807

ETIM

ETIM 2.0 EC000943
ETIM 3.0 EC000943
ETIM 4.0 EC000943
ETIM 6.0 EC000943
ETIM 7.0 EC000943

UNSPSC

UNSPSC 6.01 30212010
UNSPSC 7.0901 39121610
UNSPSC 11 39121610
UNSPSC 12.01 39121610
UNSPSC 13.2 39121620
UNSPSC 18.0 39121620
UNSPSC 19.0 39121620
UNSPSC 20.0 39121620
UNSPSC 21.0 39121620
 
 
AIS.Hensch | e-mail: info@ais-deutschland.de | +49 (0) 511-69608385 | 2021 ©


 
X
 
X