Featured Products!
Cable Tie GT, 200/2.5 NA, 8.1kg, Polyamide 6.6, -40..85°C, UL94 V2, 100stk/pck, UL E75050, Lloyd’s, GL 59425-08HH, Mil-23190D, natural
Cable Tie GT, 200/2.5 NA, 8.1kg, Polyamide 6.6, -40..85°C, UL94 V2, 100stk/pck, UL E75050, Lloyd’s, GL 59425-08HH, Mil-23190D, natural



Coupling Relais PSR-PC20-1NO-1NC-24DC-SC, 1stk/pck, Phoenix
Image is illustrative
Coupling Relais PSR-PC20-1NO-1NC-24DC-SC, 1stk/pck, Phoenix
Code: 2700577
Price
120,60 €  /pc
Manufacturer :
Availability:
21 days
Weight:
0.1891 kg/pc
Volume:
0.0004 m3/pc
 

Coupling Relay PSR-PC20-1NO-1NC-24DC-SC, 1pcs/pck, Phoenix

Note

Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
Use in potentially explosive areas is not permitted in China.

Dimensions

Width 12.5 mm
Height 112.2 mm
Depth 114.5 mm

Ambient conditions

Ambient temperature (operation) -40 °C ... 70 °C (observe derating)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing)
Max. permissible humidity (storage/transport) 75 % (on average, 85% infrequently, non-condensing)
Maximum altitude ≤ 2000 m (Above sea level)

Power supply

Rated control circuit supply voltage US 24 V DC -15 % / +10 % (A1/A2)
20.4 V DC ... 26.4 V DC
Rated control supply current IS typ. 50 mA
Input voltage range "0" signal 0 V DC ... 5 V DC (for safe Off)
Input current range "0" signal 0 mA ... 2 mA (for safe Off)
Power consumption at US typ. 1.2 W
Inrush current typ. 400 mA (Δt < 10 µs at Us)
Filter time max. 2 ms (at A1-A2; test pulse width)
≥ 100 ms (at A1-A2; test pulse rate)
Diagnostic supply voltage UD 24 V DC -15 % / +10 % (31/A2, TBUS)
Input current at UD 6 mA (at 31-A2 for UD; depending on load + 100 mA at M1 and 32)
Inrush current at UD typ. 2.5 A (Δt < 20 µs at UD)
Protective circuit Serial protection against polarity reversal 33 V suppressor diode (A1/A2)33 V suppressor diode (31/A2)

Relay outputs: enabling current path

Output name Enabling current path
Output description 2 N/O contacts in series, without delay, floating
Number of outputs 1 (safety-related N/O contacts: 13/14 (13F/14))
Contact type 1 enabling current path
Contact material AgSnO2
Switching voltage min. 12 V AC/DC
max. 250 V AC/DC (Observe the load curve)
Limiting continuous current 6 A (13/14 for high-demand)
4 A (13F/14 with high/low demand, 13/14 with low demand)
Inrush current min. 3 mA
max. 6 A (N/O contact 13/14)
4 A (N/O contact 13F/14)
Sq. Total current 36 A2 (13/14, see to derating)
16 A2 (13F/14, see to derating)
Switching capacity min. 60 mW
Switching frequency max. 0.5 Hz
Mechanical service life 10x 106 cycles
Switching capacity according to IEC 60947-5-1 4 A (24 V (DC13); N/O contact 13/14)
5 A (250 V (AC15); N/O contact 13/14)
4 A (250 V (AC15); N/O contact 13F/14)
Output fuse 6 A gL/gG (N/O contact 13/14)
4 A gL/gG (for low-demand applications)

Relay outputs: return current/signaling current path

Output name Confirmation current path
Output description 2 N/C contacts in series, without delay, not floating (reference ground: A2)
Number of outputs 1 (safety-related N/C contacts: 31/32)
Contact type 1 confirmation current path
Contact material AgCuNi, + Au
Switching voltage min. 20.4 V DC
max. 26.4 V DC
Limiting continuous current 100 mA
Inrush current min. 1 mA
max. 100 mA
Switching capacity min. 20 mW
Switching frequency max. 0.5 Hz
Mechanical service life 10x 106 cycles
Output fuse 150 mA Fast-blow

Alarm outputs

Designation M1
Output description PNP
Number of outputs 1 (non-safety-related)
Voltage approx. 22 V DC (UD - 2 V)
Current max. 100 mA
Maximum inrush current 500 mA (Δt = 1 ms at Us)
Short-circuit protection no
Output fuse 150 mA fast blow

Times

Typical pickup time at US < 100 ms (with Us when controlled via A1)
Typical release time at US < 35 ms (when controlled via A1)
Recovery time 500 ms

General

Relay type Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Nominal operating mode 100% operating factor
Net weight 189.1 g
Mounting position vertical, horizontal, with front of module upward
Mounting type DIN rail mounting
Assembly instructions See derating curve
Degree of protection IP20
Min. degree of protection of inst. location IP54
Housing material Polyamide
Housing color yellow
Operating voltage display 1 x yellow LED
Status display 1 x green LED
Indication 1 x red LED

Connection data

Connection method Screw connection
pluggable Yes
Conductor cross section solid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross-section AWG 24 ... 12
Stripping length 7 mm
Screw thread M3
Torque 0.5 Nm ... 0.6 Nm

Safety-related characteristic data

Stop category in accordance with IEC 60204 0
Designation IEC 61508 - High demand
Safety Integrity Level (SIL) 3
Designation IEC 61508 - Low demand
Safety Integrity Level (SIL) 3
Designation EN 50156
Safety Integrity Level (SIL) 3

Standards and Regulations

Designation Air clearances and creepage distances between the power circuits
Standards/regulations DIN EN 50178, EN 60079-15
Rated insulation voltage 250 V AC
Rated surge voltage/insulation Safe isolation, 6 kV reinforced insulation from control circuit, start circuit, confirmation current path, signal output to the enabling current path; 4 kV/basic insulation between all current paths and housing
Degree of pollution 2
Overvoltage category III
Shock 15g
Vibration (operation) 10 Hz ... 150 Hz, 2g
Conformance CE-compliant
ATEX  II 3 G Ex nA nC IIC T4 Gc
IECEx Ex nA nC IIC T4 Gc
UL, USA/Canada cULus
Class I, Zone 2, AEx nA nC IIC T4 / Ex nA nC IIC Gc T4 X
Class I, Div. 2, Groups A, B, C, D, T4
GL C, EMC2
Environmental simulation test ISA-S71.04 (G3)

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

ECLASS

ECLASS 10.0.1 27371819
ECLASS 11.0 27371819
ECLASS 4.0 40020600
ECLASS 4.1 40020600
ECLASS 5.0 27371900
ECLASS 5.1 27371900
ECLASS 6.0 27371800
ECLASS 7.0 27371819
ECLASS 9.0 27371819

ETIM

ETIM 6.0 EC001449
ETIM 7.0 EC001449

UNSPSC

UNSPSC 18.0 39122205
UNSPSC 19.0 39122205
UNSPSC 20.0 39122205
UNSPSC 21.0 39122205
 
 