Digital DC Output Module Flex, 8-ch., 24VDC, 80mA 24VDC, TS35, panel mount, Allen-Bradley Code:
1794-OB8EP
Price (indicative)
Manufacturer
:
Availability:
21 days
|
Weight:
0.127 kg/pc
|
Volume:
0.0004 m3/pc
|
|
|
|
|
Digital DC Output Module Flex, 8-ch., 24VDC, 80mA 24VDC, TS35 ?panel mount, Allen-Bradley
DESCRIPTIONS
-
Flex™ Digital DC Output Module, Number Of Channels: 8 (Non-Isolated), Output: On-State Voltage Range: 10 VDC Min, 24 VDC Nominal, 31.2 VDC Max, Off-State Voltage: 31.2 VDC Max, On-State Current: 1 MA Min Per Channel, 2 A Maximum Per Channel, Output Current Rating: Maximum 2 A Per Output, 10 A Maximum Per Module, Off-State Leakage: 0.5 MA Max, On-State Voltage Drop: 0.2 VDC Max, Voltage Rating: 19.2 - 31.2 VDC (Includes 5% AC Ripple), Current Rating: Supply: 80 MA At 24 VDC, Isolation: 850 VDC For 1 SEC Between User And System, Enclosure: Open Type, Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 30 - 1000 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 30 MHZ, Connection Cables: 12 AWG Stranded Copper Wire, Communication: EtherNet/IP, ControlNet, DeviceNet And Profibus DP, Mounting: DIN Rail, Panel, Length: 3.7 IN, Width: 2.7 IN, Height: 3.7 IN, Temperature Rating: 32 - 131 DEG F, Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 5 G, Shock: 30 G (Operating), 50 G (Non-Operating), Response Time: Delay (Off To On/On To Off): 0.5 MS/1 MS, Power Dissipation: 5.5 W At 31.2 VDC, Output Type: Current Sourcing, Surge Current: 4 A For 10 MS, Repeatable Every 3 SEC, Surge Transient Immunity: Plus/Minus 1 KV Line-Line(DM) And Plus/Minus 2 KV Line-Earth(CM) On Signal Ports, Bus Rating: 73 MA, Indicator: 8 Yellow Status, 8 Red Fault, Keyswitch Position: 2, Standard/Approvals: C/US UL listed, CSA certified, CE-ATEX, CE-EMC, C-TICK, GOST_R, KCC certified, MARINE-ABS, MARINE-BVS, MARINE-DNV, MARINE-GL, MARINE-KRS, MARINE-LR, ROSTECHNADZOR, TUV-FS, Application: For in-cabinets
SPECIFICATIONS
-
-
Item Name: Digital DC Output Module
-
Sub Brand: Flex™
-
Number Of Channels: 8 (Non-Isolated)
-
Output: On-State Voltage Range: 10 VDC Min, 24 VDC Nominal, 31.2 VDC Max, Off-State Voltage: 31.2 VDC Max, On-State Current: 1 MA Min Per Channel, 2 A Maximum Per Channel, Output Current Rating: Maximum 2 A Per Output, 10 A Maximum Per Module, Off-State Leakage: 0.5 MA Max, On-State Voltage Drop: 0.2 VDC Max
-
Voltage Rating: 19.2 - 31.2 VDC (Includes 5% AC Ripple)
-
Current Rating: Supply: 80 MA At 24 VDC
-
Isolation: 850 VDC For 1 SEC Between User And System
-
Enclosure: Open Type
-
Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 30 - 1000 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 30 MHZ
-
Connection Cables: 12 AWG Stranded Copper Wire
-
Communication: EtherNet/IP, ControlNet, DeviceNet And Profibus DP
-
Mounting: DIN Rail, Panel
-
Length: 3.7 IN
-
Width: 2.7 IN
-
Height: 3.7 IN
-
Temperature Rating: 32 - 131 DEG F
-
Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 5 G, Shock: 30 G (Operating), 50 G (Non-Operating)
-
Response Time: Delay (Off To On/On To Off): 0.5 MS/1 MS
-
Power Dissipation: 5.5 W At 31.2 VDC
-
Output Type: Current Sourcing
-
Indicator: 8 Yellow Status, 8 Red Fault
-
Surge Transient Immunity: Plus/Minus 1 KV Line-Line(DM) And Plus/Minus 2 KV Line-Earth(CM) On Signal Ports
-
Surge Current: 4 A For 10 MS, Repeatable Every 3 SEC
-
Keyswitch Position: 2
-
Bus Rating: 73 MA
FEATURES
-
The FLEX I/O module plugs into the terminal base, connecting to the I/O bus and field devices. Since there is no direct wiring to the I/O module, modules can be removed and inserted under power, enabling to change modules without disturbing field wiring, other I/O modules, or system power. This eliminates costly downtime and the inefficiencies of restarting a system. - LED for each channel indicating status of: corresponding input device, output signal
- Electronic fused (EP) module acts to open the output when a fault occurs, the "fuse" can be reset by operating a pushbutton, via software, or by cycling the input power, fault status is provided to the processor
- Standards: C/US UL listed, CSA certified, CE-ATEX, CE-EMC, C-TICK, GOST_R, KCC certified, MARINE-ABS, MARINE-BVS, MARINE-DNV, MARINE-GL, MARINE-KRS, MARINE-LR, ROSTECHNADZOR, TUV-FS
- Applications: For in-cabinets
|
|
|
|