Elit logo e-Elit - leading
electronic and automation component
online distributor
Customer service Mo-Fr 9-17
Call: +49 (0) 511-69608385

Elit shopping basket
Items: Total:
0
0,00 €
    search
Log in
Username/Email Address:

Password:
Show all products categ.
Need assistance?
Featured Products!
Cable Tie GT, 200/2.5 NA, 8.1kg, Polyamide 6.6, -40..85°C, UL94 V2, 100stk/pck, UL E75050, Lloyd’s, GL 59425-08HH, Mil-23190D, natural
Cable Tie GT, 200/2.5 NA, 8.1kg, Polyamide 6.6, -40..85°C, UL94 V2, 100stk/pck, UL E75050, Lloyd’s, GL 59425-08HH, Mil-23190D, natural



Digital DC Combination I/O Module Flex, 16-ch., 0.5A per output, cv 24VDC, Allen-Bradley
Image is illustrative
Digital DC Combination I/O Module Flex, 16-ch., 0.5A per output, cv 24VDC, Allen-Bradley
Code: 1794-IB16XOB16P
Price (indicative)
250,80 €  /pc
Manufacturer :
Availability:
21 days
Weight:
0.119 kg/pc
Volume:
0.0004 m3/pc
 

Digital DC Combination I/O Module Flex, 16-ch., 0.5A per output, cv 24VDC, Allen-Bradley

DESCRIPTIONS
Flex™ Digital DC Combination I/O Module, Number Of Channels: 16 (Non-Isolated), Input: On-State Voltage: 10 VDC (Minimum), 24 VDC Nominal, 31.2 VDC (Maximum), On-State Current: 2 MA (Minimum), 8.8 MA Nominal At 24 VDC, 12.1 MA (Maximum), Off-State Voltage: 5 VDC (Maximum), Off-State Current: 1.5 MA (Minimum), Output: On-State Voltage Range: 10 VDC Min, 24 VDC Nominal, 31.2 VDC Max, Output Current Rating: 0.5 A Per Output, 8 A Per Module Max, Off-State Voltage: 31.2 V Max, On-State Current: 1 MA Min Per Channel, 0.5 A Maximum Per Channel, 8 A Maximum Per Module, On-State Voltage Drop: 0.5 VDC At 1 A Max, Voltage Rating: 24 VDC, Current Rating: Output Current Rating: 0.5 A Per Output, 8 A Per Module Max, Off-State Leakage: 0.5 MA Max, Output Supply Current: 78 MA At 10 VDC, 137 MA At 24 VDC, 168 MA At 31.2 VDC, Isolation: Input To Backplane, Output To Backplane, Input Channels To Output Channels - 1250 VAC (RMS) Isolation, Tested At 2121 VDC For 1's Between User And System, No Isolation Between Individual Channels, Enclosure: Open Type, Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 30 - 1000 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 30 MHZ, Connection Cables: 22 - 12 AWG Stranded Copper Wire, Mounting: DIN Rail, Panel, Length: 3.7 IN, Width: 2.7 IN, Height: 3.7 IN, Temperature Rating: 32 - 131 DEG F, Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 5G, Shock: 30 G (Operating), 50G (Non-Operating), Response Time: Output Signal Delay - Off To On: 0.5 MS Maximum, On To Off - 1 MS Maximum, Input Filter Time - Off To On/On To Off: 0.25, 0.5, 1, 2, 4, 8, 16, 32 MS, (0.25 MS Default), Power Dissipation: 7 W At 31.2 VDC, Surge Current: 1.5 A For 50 MS, Repeatable Every 2 SEC, Indicator: Input: 16 Yellow Status, Output: 16 Yellow Status, Surge Transient Immunity: Plus/Minus 1 KV Line-Line(DM) And Plus/Minus 2 KV Line-Earth(CM) On Signal Ports, Impedance: Input: 2.5 KOHM, Keyswitch Position: 2, Bus Rating: 80 MA, Standard/Approvals: C/US UL listed, CSA certified, CE-EMC marked, C-TICK certified, GOST_R certified, KCC certified, MARINE-ABS certified, MARINE-BVS certified, MARINE-DNV certified, MARINE-GL certified, MARINE-LR certified, ROSTECHNADZOR, Application: For in-cabinets
SPECIFICATIONS
  • Item Name: Digital DC Combination I/O Module

  • Sub Brand: Flex™

  • Number Of Channels: 16 (Non-Isolated)

  • Input: On-State Voltage: 10 VDC (Minimum), 24 VDC Nominal, 31.2 VDC (Maximum), On-State Current: 2 MA (Minimum), 8.8 MA Nominal At 24 VDC, 12.1 MA (Maximum), Off-State Voltage: 5 VDC (Maximum), Off-State Current: 1.5 MA (Minimum)

  • Output: On-State Voltage Range: 10 VDC Min, 24 VDC Nominal, 31.2 VDC Max, Output Current Rating: 0.5 A Per Output, 8 A Per Module Max, Off-State Voltage: 31.2 V Max, On-State Current: 1 MA Min Per Channel, 0.5 A Maximum Per Channel, 8 A Maximum Per Module, On-State Voltage Drop: 0.5 VDC At 1 A Max

  • Voltage Rating: 24 VDC

  • Current Rating: Output Current Rating: 0.5 A Per Output, 8 A Per Module Max, Off-State Leakage: 0.5 MA Max, Output Supply Current: 78 MA At 10 VDC, 137 MA At 24 VDC, 168 MA At 31.2 VDC

  • Isolation: Input To Backplane, Output To Backplane, Input Channels To Output Channels - 1250 VAC (RMS) Isolation, Tested At 2121 VDC For 1's Between User And System, No Isolation Between Individual Channels

  • Enclosure: Open Type

  • Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 30 - 1000 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 30 MHZ

  • Connection Cables: 22 - 12 AWG Stranded Copper Wire

  • Mounting: DIN Rail, Panel

  • Length: 3.7 IN

  • Width: 2.7 IN

  • Height: 3.7 IN

  • Temperature Rating: 32 - 131 DEG F

  • Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 5G, Shock: 30 G (Operating), 50G (Non-Operating)

  • Response Time: Output Signal Delay - Off To On: 0.5 MS Maximum, On To Off - 1 MS Maximum, Input Filter Time - Off To On/On To Off: 0.25, 0.5, 1, 2, 4, 8, 16, 32 MS, (0.25 MS Default)

  • Power Dissipation: 7 W At 31.2 VDC

  • Indicator: Input: 16 Yellow Status, Output: 16 Yellow Status

  • Surge Transient Immunity: Plus/Minus 1 KV Line-Line(DM) And Plus/Minus 2 KV Line-Earth(CM) On Signal Ports

  • Surge Current: 1.5 A For 50 MS, Repeatable Every 2 SEC

  • Impedance: Input: 2.5 KOHM

  • Keyswitch Position: 2

  • Bus Rating: 80 MA

FEATURES

The FLEX I/O module plugs into the terminal base, connecting to the I/O bus and field devices. Since there is no direct wiring to the I/O module, you can remove and insert modules under power, enabling you to change modules without disturbing field wiring, other I/O modules, or system power. This eliminates costly downtime and the inefficiencies of restarting a system.

  • Isolated inputs and outputs can be used in applications such as motor control centers, where individual control transformers are used
  • Protected (P) outputs have electronic protection, which acts to shut the module down in reaction to a short circuit, overload, or over-temperature condition
  • Recovery from shutdown is automatic upon removal of the output fault. No fault status is provided to the processor
  • LED for each channel indicating status of: corresponding input device, output signal
  • Standards: C/US UL listed, CSA certified, CE-EMC marked, C-TICK certified, GOST_R certified, KCC certified, MARINE-ABS certified, MARINE-BVS certified, MARINE-DNV certified, MARINE-GL certified, MARINE-LR certified, ROSTECHNADZOR
  • Applications: For in-cabinets
 
 
AIS.Hensch | e-mail: info@ais-deutschland.de | +49 (0) 511-69608385 | 2021 ©


 