Image is illustrative
|
Digital Output Module MicroLogix, 8-ch., VAC/VDC Relais, TS35, panel mount, Allen-Bradley Code:
1762-OW8
Price (indicative)
Manufacturer
:
Availability:
ask for dd
|
Weight:
0.218 kg/pc
|
Volume:
0.001 m3/pc
|
|
|
|
|
Output Module MicroLogix, 8 outputs VAC/VDC Relay, Rockwell Automation
DESCRIPTIONS
MicroLogix™ Digital Output Module, Type: Discrete, Number Of Channels: 8 (Isolated), Output: Off-State Leakage: 0 MA, On-State Current: 10 MA At 5 VDC, Continuous Current Per Point: 2.5 A, Continuous Current Per Common: 8 A, Continuous Current Per Module: 16 A, Voltage Rating: 5 - 265 VAC/5 - 125 VDC, Isolation: Verified By One Of The Following Dielectric Tests: 1836 VAC For 1 SEC Or 2596 VDC For 1 SEC, 265 VAC Working Voltage (Basic Insulation), 150 VAC Working Voltage (IEC Class 2 Reinforced Insulation), Enclosure: IP20, Rfi Suppression: Radiated: 10 V/M, 80 - 1000 MHZ, 80% Amplitude Modulation, 900 MHZ Keyed Carrier, Conducted: 10 V, 0.15 - 80 MHZ, Mounting: DIN Rail, Panel, Length: 1.575 IN, Width: 3.425 IN, Height: 3.543 IN, Temperature Rating: -32 To 131 DEG F, Environmental Conditions: Relative Humidity: 5 - 95% (Non-Condensing), Vibration - Operating: 10 - 500 HZ, 5 G, 0.015 IN Peak-To-Peak, Relay Operation: 2 G, Shock - Operating: 30 G Panel Mounted, 20 G DIN-Rail Mounted, Relay Operation: 7.5 G Panel Mounted, 5 G DIN Rail Mounted, NonOperating: 40 G Panel Mounted, 30 G DIN Rail Mounted, Response Time: Signal Delay - On Delay: 10 MS, Off Delay: 10 MS, Power Dissipation: Heat Dissipation: 2.9 W, Bus Rating: Bus Current Draw: 80 MA At 5 VDC (0.4 W), 90 MA At 24 VDC (2.16 W), Surge Transient Immunity: 2 KV Common Mode, 1 KV Differential Mode, Indicator: LED, Standard/Approvals: C/US UL listed, UL 508, UL 1604, CSA C22.2, file number 213, CE marked, class I, division 2, hazardous location, groups A, B, C, D, C-tick, GOST_R, KCC certified, marine-ABS, marine-BVS, marine-DNV, marine-GL, marine-KRS, marine-LR, ROSTECHNADZOR
|
|
SPECIFICATIONS
- Item Name: Digital Output Module
- Type: Discrete
- Sub Brand: MicroLogix™
- Number Of Channels: 8 (Isolated)
- Output: Off-State Leakage: 0 MA, On-State Current: 10 MA At 5 VDC, Continuous Current Per Point: 2.5 A, Continuous Current Per Common: 8 A, Continuous Current Per Module: 16 A
- Voltage Rating: 5 - 265 VAC/5 - 125 VDC
- Isolation: Verified By One Of The Following Dielectric Tests: 1836 VAC For 1 SEC Or 2596 VDC For 1 SEC, 265 VAC Working Voltage (Basic Insulation), 150 VAC Working Voltage (IEC Class 2 Reinforced Insulation)
- Enclosure: IP20
- Rfi Suppression: Radiated: 10 V/M, 80 - 1000 MHZ, 80% Amplitude Modulation, 900 MHZ Keyed Carrier, Conducted: 10 V, 0.15 - 80 MHZ
- Mounting: DIN Rail, Panel
- Length: 1.575 IN
- Width: 3.425 IN
- Height: 3.543 IN
- Temperature Rating: -32 To 131 DEG F
- Environmental Conditions: Relative Humidity: 5 - 95% (Non-Condensing), Vibration - Operating: 10 - 500 HZ, 5 G, 0.015 IN Peak-To-Peak, Relay Operation: 2 G, Shock - Operating: 30 G Panel Mounted, 20 G DIN-Rail Mounted, Relay Operation: 7.5 G Panel Mounted, 5 G DIN Rail Mounted, NonOperating: 40 G Panel Mounted, 30 G DIN Rail Mounted
- Response Time: Signal Delay - On Delay: 10 MS, Off Delay: 10 MS
- Power Dissipation: Heat Dissipation: 2.9 W
- Indicator: LED
- Surge Transient Immunity: 2 KV Common Mode, 1 KV Differential Mode
- Bus Rating: Bus Current Draw: 80 MA At 5 VDC (0.4 W), 90 MA At 24 VDC (2.16 W)
FEATURES
The 1762 MicroLogix expansion I/O modules are compatible with MicroLogix 1100, MicroLogix 1200, and MicroLogix 1400 controllers. Install the expansion I/O modules to the right of the controller, either on a panel with two mounting screws or on a DIN rail. Use digital I/O modules in many combinations, up to the maximum supported by the controller. The current loading capacity of the controller’s built-in power supply may limit the actual number of I/O modules that can be connected to the controller.
Integrated high-performance I/O bus
Software keying to prevent incorrect positioning within the system
Finger-safe terminal blocks for I/O wiring
Label to record I/O terminal designations
Network support includes EtherNet/IP, DeviceNet, and DH-485 (local only)
Standards: C/US UL listed, UL 508, UL 1604, CSA C22.2, file number 213, CE marked, class I, division 2, hazardous location, groups A, B, C, D, C-tick, GOST_R, KCC certified, marine-ABS, marine-BVS, marine-DNV, marine-GL, marine-KRS, marine-LR, ROSTECHNADZOR
|
|
|
|