				Image is illustrative
			 
 
 | 
Calibratable Temperature Measuring Transducer THERMASGARD® HFTM-I, 8 range (-40..150°C), 0point cor. (±10°K), output 4..20mA, Pt1000 cl.B, 2/3Draht, -30..70°C, ss1.4571 V4A Ø6mm L50mm, cv 15..36VDC, IP65 Code:
		1101-1152-0219-920
 
 
Price  
				Manufacturer
			: 
| 
 Availability:
			 
14 days 
 | 
 Weight:  
0.216 kg/pc 
 | 
 | 
 | 
 
 
 | 
 | 
 
 
 | 
 
Calibratable Temperature Measuring Transducer THERMASGARD® HFTM-I, 8 range (-40..150°C) ?0point cor. (±10°K), output 4..20mA, Pt1000 cl.B, 2/3wire, -30..70°C, ss1.4571 V4A Ø6mm L50mm, cv 15..36VDC, IP65, S+S RegeltechnikTHERMASGARD® HFTM-I
                        Item No. 1101-1152-0219-920
                        
                             EAN 4 251325 600680
                        
                    
						Calibratable temperature measuring transducer with sleeve sensor THERMASGARD® HFTM with eight switchable RPTM 1 measuring ranges, continuous output, without ⁄ with optional display (for indicating the actual temperature), terminal box enclosure made of impact-resistant plastic, enclosure cover with quick-locking screws. The temperature transmitter with remote sensor is used to detect temperatures in liquid and gaseous media e.g. if installed in an immersion sleeve or as a duct sensor. The sensors are factory-calibrated. Adjustment ⁄ fine adjustment by the user is possible (zero point offset is adjustable).
					 
| Voltage supply | 
				
						15...36 V DC depending on working resistance, residual ripple stabilised ± 0.3 V | 
 
| Power consumption | 
				
						< 1,0 VA ⁄ 24 V DC
 < 2,2 VA ⁄ 24 V AC
					
			 | 
 
| Working resistance | 
				
						Ra(ohm) = (Ub -14 V) ⁄ 0.02 A for I variant
					
			 | 
 
| Deviation of humidity | 
± 0.2 K at +25 °C | 
 
| Output | 
4...20 mA | 
 
| Sensor | 
Pt1000, DIN EN 60751, class B | 
 
| Connection type | 
2- or 3-wire connection | 
 
| Measuring ranges | 
multi-range switching with 8 switchable measuring ranges, 
see table (other ranges optional) 
with manual zero point correction (± 10 K)
 | 
 
| Ambient temperature | 
Measuring transducer –30...+70 °C | 
 
| Protective tube (sensor sleeve) | 
				
						stainless steel, 1.4571, V4A, Ø = 6 mm, 
nominal length (NL) = 50 mm 
(other dimensions optional) 
cable entry stamped (optional rolled)
					
			 | 
 
| Electrical connection | 
				
						0.14 - 1.5 mm² 
via terminal screws on circuit board
					
			 | 
 
| Enclosure | 
				
						plastic, UV-stabilised,  material polyamide,
30 % glass-globe reinforced, 
with quick-locking screws 
(slotted ⁄ Phillips head - combination), 
colour traffic white (similar to RAL 9016)
					
			 | 
 
| Enclosure dimensions | 
72 x 64 x 37,8 mm (Tyr 1) | 
 
| Cable gland | 
				
						2x M 12 x 1.5 (Y-adapter); with strain relief, 
exchangeable, max. inner diameter 6 mm
					
			 | 
 
| Connection cable | 
				
						silicone, SiHF, 2 x 0.25 mm², KL = 1.5 m (other lengths and 
range limits optional, e.g. PTFE leads up to +250 °C 
or glass fibre with steel wire mesh up to +350°C)
					
			 | 
 
| Permissible air humidity | 
< 95 % r. H., non-precipitating air | 
 
| Protection class | 
III (according to EN 60 730) | 
 
| Protection type | 
IP 65 (according to EN 60 529) humidity-tight stamped 
IP 68 (optional watertight compound-filled) rolled 
IP 54 (optional glass fibre cable)
					
			 | 
 
| Standards | 
				
						CE conformity, 
electromagnetic compatibility according to EN 61326, 
according to EMC Directive 2014 ⁄ 30 ⁄ EU
					
			 | 
 
 
 | 
 
  
 | 
 
 
 | 
 
 
  
 
 
 
 |